top of page
Patient Room

Portable In-Room Infectious Patient Isolation and air purification and disinfection System from Abatement HEPA-CARE® HC800FDUV
- Quickly Converts any Patient Room into a Negative Pressure Isolation Room

- Cleans and disinfects indoor air throughout medical institutions, including patient rooms, doctors' offices, procedure cabinets, and more

​

The HC800FDUV floor model is equipped with an H14 HEPA filter tested and certified to capture at least 99.995% of microscopic particles 0.3 microns in size and high output germicidal UV lamp.

HC800FD

Replacement

AIR Filters
& UV Lamp

MEDICAL GRADE PORTABLE AIR PURIFIER HC800FDUV

button.jpg
hc800-min.png
UV-Lamp.jpg

Net Weight with Filters lbs - .83 

Dimensions (L x W x H) in - 21.125 x 20.375 x 47.5

Electrical Rating V, Hz, A - 120 VAC, 60 Hz, 15 A 

Airflow, max. with clean filters CFM - Up to 925 

Maximum Operating Amps - amps 6 or less 

Motorized Impeller - 2 EC Motorized Impellers 

Motorized Impeller Speed Setting - 5 touch screen speed settings 

Power Cord - 10ft. 14/3 AWG SJT cord with 15 A/120 volt AC hospital grade plug 

Sound Level @ 5 Feet - dBA 37 - 59 

HEPA Filter Efficiency - 99.995% @ 0.3 microns, gel seal 

Cabinet Material - Powder coated aluminum; riveted and sealed 

First Stage Prefilter 1 ea. - HC1802AM, 2” ASHRAE MERV 8 pleated 

Optional VAPOR-LOCK® Prefilter - 1 ea. HC1802CF 

HEPA Filter 1 ea. - HC1836-H14

UV Lamp - UV425 ultra-high output UVGI lamp

HC800FDUV MEDICAL GRADE PORTABLE HEPA AIR PURIFIER TECHNICAL CHARACTERISTICS

High-performance motorized blowers produce peak rated airflow from 150 up-to 925cfm*, and can typically maintain 12 or more air changes per hour (ACH) in areas as large as 4,000-4,625 ft3*. The upright, slender-profile design with easy-rolling, swivel casters facilitate the use of the HC800FD in tight spaces.

When not in use for negative pressure patient isolation, the versatile HC800FD can function as a recirculating HEPA air cleaner, reducing airborne pathogen counts in high-risk areas such as ER waiting rooms and treatment areas.
Air laden is pulled through two filter stages:

  • A 2" particulate pre-filter

  • A pharmaceutical-grade HEPA filter with silicone-gel seal and anodized aluminum frame

Remove Odors and Gases With a VAPOR-LOCK® Carbon Filter

Optional VAPOR-LOCK carbon pre-filters are available for the HC800FD or HC800FDUV, to remove airborne gas phase contaminants and odors from the air. These filters are used in place of the standard particulate pre-filter. 

With thousands of units in service, the state-of-the-art HC800 series filtration systems create an unmatched record of reliable performance operating 24/7/365.
The new HC800 models feature:

  • Portability - Narrow, upright design with two smooth-rolling fixed casters and two swivel casters with foot brakes make it easy to deploy

  • Powerful Airflow - Dual energy-efficient motorized impellers rated for 100,000 hours of maintenance-free operation

  • Unique Zero-Bypass Dual Cabinet Design - Added assurance that contaminated air can't bypass the HEPA filter

  • Durable Cabinet - powder-coated aluminum and advanced assembly techniques create a refined look and are easy to decontaminate and maintain

  • Safety Certification - Certified as a Class II Medical Devices under FDA 510K and NRTL certified to conform with relevant UL and CSA safety standards

  • Control Panel - Intuitive digital touch screen

Long-Life HEPA Filter with Strong Aluminum Frame

Each pharmaceutical-grade HEPA filter from Abatement Technologies is individually tested and certified in accordance with the Institute of Environmental Sciences and Technology IEST-RP-CC001 to provide minimum filtration efficiency of 99.995% against a 0.3 micron challenge aerosol.

Silicone-Gel Seal Protects Against Contaminated Air Bypass

A downward-facing flange imbeds into a silicone-gel seal creating a channel that forces air through the HEPA filter and protects against the contaminated air bypassing the filter.

Hinged Door for Rapid Filter Replacement

Hinged, front door secures with two Phillips machine screws and provides quick access to both the HEPA filter and the 2” particulate pre-filter for replacement or maintenance.

Integrated digital touchscreen

High-visibility, color LCD touch screen controls. Intuitive, menu-driven screens are accessed after opening the Password Entry Screen:

  • Digital 3.25" LCD touch screen

  • Password protection

  • Five airflow settings

  • Menu-driven display for monitoring various operating parameters

  • Increased reliability Green ‘Unit On’ indicator that illuminates when the unit is powered

  • Yellow ‘Warning" Change Pre-Filter’ indicator that illuminates when the pre-filter and/or HEPA filter are approaching the load limit

  • Red ‘Change HEPA Filter’ indicator that illuminates when the HEPA is loaded

  • LCD display for status indication, setup and operating modes

  • Modular design for ease of service

Safety Certified

All Abatement HEPA-CARE units have been tested by a Nationally Recognized Testing Laboratory (NRTL) and carry the marks certifying that they comply with applicable OSHA, UL and CSA electrical safety standards. Filters meet UL900 flammability standards.

bottom of page